Skip to content
Draft
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension


Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
337 changes: 237 additions & 100 deletions .github/copilot-instructions.md

Large diffs are not rendered by default.

9 changes: 4 additions & 5 deletions .github/workflows/validate.yml
Original file line number Diff line number Diff line change
Expand Up @@ -38,11 +38,10 @@ jobs:
run: |
pytest tests/ -v --tb=short

# Commented out until ready for HACS publication
# - name: HACS validation
# uses: hacs/action@main
# with:
# category: integration
- name: HACS validation
uses: hacs/action@main
with:
category: integration

- name: Hassfest validation
uses: home-assistant/actions/hassfest@master
85 changes: 60 additions & 25 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -40,30 +40,50 @@ Currently supports NIBE heat pumps via MyUplink integration, with plans to add s
- **Proactive debt prevention** - trend-based future DM prediction
- **Effect tariff** (peak avoidance) - predictive 15-min protection
- **Prediction/Learning** (self-tuning) - learned thermal model for pre-heating
- **Weather compensation** (mathematical flow temp) - André Kühne + Timbones formulas
- **Weather compensation** (mathematical flow temp) - the **EN 442 emitter law**
- **Weather prediction** (pre-heating) - time-aware cold snap protection
- **Spot price** (cost reduction) - forward-looking optimization with adaptive horizon
- **Comfort** (tolerance) - reactive temperature correction

### 🌍 Global Climate Adaptation
Automatic latitude-based zone detection (Arctic to Mediterranean):
- **Extreme Cold** (66.5°N+): Kiruna, Tromsø - DM -800 to -1200 normal
- **Very Cold** (60.5-66.5°N): Luleå, Umeå - DM -600 to -1000 normal
- **Cold** (56-60.5°N): Stockholm, Oslo, Helsinki - DM -450 to -700 normal
- **Moderate Cold** (54.5-56°N): Copenhagen, Malmö - DM -300 to -500 normal
- **Standard** (<54.5°N): Paris, London - DM -200 to -350 normal

**No configuration needed** - uses Home Assistant latitude. DM -1500 absolute maximum enforced globally.

### 🧠 Self-Learning Capability
Learns your building over 7-14 days:
Automatic latitude-based zone detection (Arctic to Mediterranean). The ranges below are each zone's
**base** range — what is normal **at that zone's own winter average**. They shift with the outdoor
temperature, by 20 DM per degree:

| Zone | Latitude | Winter avg | Base normal DM |
|---|---|---|---|
| **Extreme Cold** | 66.5°N+ | −20 °C | −800 to −1200 |
| **Very Cold** | 60.5–66.5°N | −12 °C | −600 to −1000 |
| **Cold** | 56–60.5°N | −8 °C | −450 to −700 |
| **Moderate Cold** | 54.5–56°N | −1 °C | −300 to −500 |
| **Standard** | <54.5°N | 0 °C | −200 to −350 |

So Stockholm's normal range is −450 to −700 **at −8 °C**, and −490 to −740 at −10 °C. Quoting the
base range as if it applied at every temperature is how four of this project's own documents came
to be wrong; see `docs/CLIMATE_ZONES.md` for the full tables.

**No configuration needed** — uses Home Assistant's latitude.

**DM −1500 is the absolute floor**, enforced globally. ⚠️ It is *not* the number that governs a real
F750: the pump's own "start addition" (menu 4.9.3) fires at **−700**, so the immersion heater engages
and works DM back up long before −1500 is approached. See `docs/research/01_degree_minutes.md`.

### 🧠 Self-Learning Capability (observing only — not yet driving your pump)
EffektGuard continuously observes your building and estimates:
- **UFH type detection** - concrete slab (6h lag) vs timber (2-3h lag) vs radiators (<1h lag)
- **Thermal mass** - building heat storage capacity (kWh/°C)
- **Heat loss coefficient** - envelope performance (W/°C)
- **Heating efficiency** - system response to offset changes (°C/°C)
- **Weather patterns** - seasonal adaptation with unusual weather detection

Predictive pre-heating uses learned parameters for intelligent load shifting.
**These estimates do not currently influence control.** Learned parameters are used for
pre-heating only once the model's confidence exceeds 70%, and confidence cannot presently
reach that: the indoor temperature is read to 0.1 °C every 5 minutes, and a building's
response over 5 minutes is smaller than the sensor's own resolution. Nothing reliable can be
learned from that, so nothing is claimed from it.

Control today is physics-based and deterministic — the heating curve, the EN 442 emitter law,
weather compensation and the degree-minute safety net — none of which depends on learning.

### ⚡ Effect Tariff Optimization
Native 15-minute (quarterly) integration:
Expand All @@ -82,7 +102,8 @@ Multi-factor forward-looking optimization combining:

### 🌡️ Weather Compensation (Mathematical)
Physics-based flow temperature optimization:
- **André Kühne formula** - validated across manufacturers (Vaillant, Daikin, NIBE, etc.)
- **EN 442 emitter law** (EN 442-1 §3.31, EN 12831, EN 1264) - validated against NIBE's own
published curve 9: it lands **0.20 °C** from it, where a straight line is out by **2.37 °C**
- **Timbones method** - radiator-specific calculations (BS EN442)
- **UFH adjustments** - concrete slab (-8°C), timber (-5°C)
- **Climate-aware margins** - automatic safety headroom by zone
Expand Down Expand Up @@ -272,22 +293,36 @@ Native quarterly (15-min) price periods:
- **Auto-discovery** - finds price entity automatically

### Weather Compensation Math

The flow temperature follows the **EN 442 emitter law** (`utils/emitter.py`) — the emitter's own
characteristic curve, not a linear offset from outdoor temperature:

```python
# André Kühne formula (universal)
TFlow = 2.55 × (HC × (Tset - Tout))^0.78 + Tset
# Demand reaches zero at the BALANCE POINT, not at room temperature:
# bodies, appliances and the sun cover the losses until several degrees below the setpoint.
balance = T_room - INTERNAL_GAINS_W / heat_loss_coefficient

# Timbones method (radiator-specific)
TFlow = ((Pin / Pout)^(1/1.3) × (DTout / DTin)) × (Tset - Tout) + Tset
phi = (balance - T_out) / (balance - T_out_design) # dimensionless relative load
T_flow = T_room + dT_design * phi**(1/n) + spread/2 # n = 1.3 radiators, 1.1 UFH
```
Combined with climate-aware safety margins (0.0-2.5°C by zone).

### Self-Learning Timeline
- **Day 1-3**: Low confidence (0.0-0.3), conservative defaults
- **Day 4-7**: Medium confidence (0.3-0.7), starts using learned params
- **Day 8-14**: High confidence (0.7-1.0), fully optimized
- **Ongoing**: Continuous refinement, seasonal adaptation
The spread is held **constant** — a heat pump modulates its circulator, it does not run a
fixed-speed pump. Combined with climate-aware safety margins (0.0–2.5 °C by zone).

### Self-Learning Status

Observations are recorded every 5 minutes into a rolling 672-entry window — **56 hours**, not
the week the window was sized for. Confidence is scored from observation count, data
consistency and time span, and learned parameters are used for pre-heating only above 70%.

At the present observation cadence that threshold is not reachable, and the integration says so
rather than pretending otherwise: a 0.1 °C indoor sensor sampled every 5 minutes quantises the
building's response into steps of 1.2 °C/h, which is larger than any real heating rate. The
consistency term is therefore honestly zero and confidence settles around 0.47.

672 observations (1 week @ 15-min) minimum for reliable learning.
**Learning does not drive your heat pump today.** Making it do so means sampling slowly enough
for the signal to exceed the sensor's resolution — a deliberate change, not a tuning tweak,
because it would put a learned model in the control path of real heating equipment.