gel-image-extractor

A tool for extracting quantitative and categorical information from gel electrophoresis images, replacing manual/eyeballed operator judgment with a standardized, reproducible pipeline.

Status

Purity workflow: implemented and tested (112 tests, all passing). Activity workflow: not started. See AGENTS.md for full project scope, data inventory, working agreements, design decisions, implementation notes (including real findings from running this against real gel images), and a "Known Limitations" section tracking open issues that shouldn't be silently fixed or forgotten. diagrams/program-flow.png (or the .mmd source) has the current architecture sketch.

MVP scope — read this before trusting a number

  • This release covers the purity workflow only. Activity/titer gel classification is a separate, not-yet-built workflow — out of scope here.
  • Treat every purity % as a first-pass estimate a human should verify, not an authoritative result. Lane detection assumes each lane is a straight vertical rectangle; real gels can curve ("smiling") or have adjacent lanes bleed together near the loading wells, and the current pipeline doesn't correct for either. Real accuracy checks against confirmed ground truth found some images matching within a few points and others off by a large margin (see AGENTS.md Implementation Status) — the gap is driven by lane-detection error, not the purity math itself.
  • Always run with --debug [PATH] and look at the annotated image before reporting a number. It draws every detected lane and band box directly on the gel photo — if a lane box looks wrong (split, merged, or offset from the real band), don't trust that lane's purity % without a manual recheck. This takes under a minute per image and is the single best safeguard this tool currently has.
  • Results are also flagged automatically where the tool itself has lower confidence: not-found (no usable signal at all), mw-mismatch (the selected band's calibrated MW doesn't match --target-mw — only possible with the default --band-selection largest, see below), largest- unverified (real calibrated MW, but no --target-mw was given to check it against — see below), heuristic (no MW info available at all, best guess only), and low_signal (likely high-dilution, purity may be inflated) — treat all five as needing extra scrutiny, not just ignoring them.
uv sync
uv run gelx purity analyze "data/decodeon_gel_images/Protein Purity/8.6.25 Protein Purity.tif" \
  --target-mw 29.267 --ladder P7719
uv run pytest

--ladder P7719 and --ladder P7717 are now real, verified options (see AGENTS.md) — ladder choice genuinely varies by team/scientist, so there's no single default. Ladder calibration is deliberately lenient — it works from however many bands are confidently detected, empirically picking whichever plausible size alignment fits best, rather than requiring every known band to resolve or assuming a fixed direction for missing ones.

Which band counts as "the target" (--band-selection, decided 2026-07-17): by default (largest), the biggest detected band in a lane always wins, regardless of MW — empirical testing against confirmed ground-truth purity found this closer to the truth than MW-based matching on this project's real images (see AGENTS.md Implementation Status). The ladder is still calibrated when possible, purely to verify the selected band against --target-mw and flag a mismatch (confidence: mw-mismatch) — never to gate the selection itself. The original MW-matching-first behavior is still available via --band-selection mw-strict (only a band within --mw-tolerance of --target-mw counts as the target at all, and --target-mw is required in this mode).

--target-mw is optional as of 2026-07-20 — but only with the default --band-selection largest. Omit it (e.g. when batch-analyzing many different proteins with no per-image expected MW on hand) and the largest band is still selected, with its real calibrated MW still reported when the ladder calibrates; confidence becomes largest-unverified instead of mw-matched/mw-mismatch, since there's nothing to check the calibrated MW against. --band-selection mw-strict still requires --target-mw (it needs a target to select a band at all) — omitting it there is a clean CLI error, not a guess. Neither mode is a solved problem: there's a confirmed, structural limitation regardless of mode — at high dilution, faint contaminant bands become undetectable before the target band does, which inflates apparent purity. This can't be fixed outright (the information isn't in the image below some dilution level), but affected lanes are flagged low_signal in the output (a "Flag" column, or a low_signal field in --csv/--json) rather than reported at face value — see AGENTS.md's Known Limitations. Treat results as directional for now, not exact.

Also see --method (which lane-geometry algorithm to use — straight rectangle by default [stable]; viterbi [promising]; ridge/snake [experimental] — see AGENTS.md Implementation Status for what each one actually is and its own caveats) — independent of --band-selection, which only decides target-band identity within whatever profile the chosen geometry produces. gelx purity analyze --help documents both in full.

What this project does (planned)

This merges two related internal NEB use cases that share the same underlying problem — image in, calibrated quantitative/categorical result out:

  • Protein purity quantification — convert an SDS-PAGE gel lane image into a quantitative purity %, without the manual baseline-selection fiddliness of tools like ImageJ.
  • Activity gel extraction — classify each well of a 96-well restriction digest stability assay gel into active / partial / dead per time point, to drive a well-position × time heatmap instead of manual scoring.

A possible third category — enzyme titer/potency assays (dilution-series agarose gels reading a potency endpoint) — was identified in newer example data but isn't scoped in yet; see QUESTIONS_FOR_USERS.md.

Both existing workflows share a common image-processing core (lane/grid segmentation, ladder detection & calibration, band/peak detection); each has its own workflow and output on top of that core. Purity was built first, and is implemented; activity hasn't been started. See AGENTS.md's "Design Decisions" section for the full reasoning.

For purity specifically, target-band identification is MW-based by default (ladder calibrated via a known lookup table or a --ladder-bands override); if the ladder can't be calibrated, the tool refuses to guess unless --allow-heuristic is explicitly passed. For activity, the plan is to classify each well against its own baseline (Normalization) image rather than requiring substrate/digest-condition data up front — both choices keep the tool fully self-contained and CLI-driven, with no external lookups required. See AGENTS.md for the full rationale.

Development

  • Stack: Python 3.11+; numpy + scipy + scikit-image for image processing; argparse for the CLI; pyproject.toml + uv for packaging/ dependencies; pytest for testing.
  • Interface: one CLI entry point with subcommands (gelx purity analyze gel.tif ...), not separate binaries per workflow. Structured so a UI can be layered on later — decided 2026-07-16 that this means hosting inside ebase (an internal NEB app), with a single-image-upload UI whose settings translate to CLI flags server-side, not a standalone executable distributed to end users; see AGENTS.md's Design Decisions for the full rationale (including why that choice matters for optional heavier dependencies like the sam-zeroshot lane-detection method). Every flag (--lane, --ladder-bands, --allow-heuristic, etc.) must be clearly documented in the CLI's own --help output, not just in external docs — end users of this tool aren't expected to be CLI-comfortable.
  • Output: human-readable table to stdout by default; --csv [PATH] and --json [PATH] are additive, optional, and can be combined. See AGENTS.md's "Design Decisions" for the exact column schema.
  • Architecture is deliberately modular/swappable: a pipeline of discrete stages, pluggable algorithms behind common interfaces (baseline correction, band detection, ladder-lane identification), and a structured result object decoupled from output formatting — several early decisions (baseline method, MW tolerance, the leftmost-lane heuristic) are expected to change once real output is in hand, so swapping any one of them should be a localized change, not a rewrite.
  • Testing is required, not optional polish — every pipeline stage needs unit tests, plus integration tests against the real example gel images in data/, plus the dilution-series self-consistency check (same sample, same purity % across dilutions — our main correctness signal, since no external ground truth exists) encoded as an actual automated test. Purity currently has 112 tests, all passing.
  • Reporting precision: purity_percent rounds to the nearest whole percent (not 1 decimal) — deliberately, given the pipeline's known real-world imprecision.
  • --debug [PATH] writes an annotated debug image showing detected lane boxes, band boxes (green = target/matched, gold = selected band's MW doesn't match --target-mwmw-mismatch, only possible with the default --band-selection largest, red = other/contaminant), a per- method/maturity banner across the top, and per-lane purity/MW labels — built for both pipeline debugging and helping an end user see how a result was reached. Always check this before trusting a number — see the MVP scope note above.
  • Lane vertical bounds (comb fringe, bottom cassette artifact) are adaptive; horizontal lane fragmentation has a validated partial fix. Gel smiling/curvature and bleed-over between wide/diffuse bands remain unaddressed — a curve-tracing prototype was explored on a separate branch (curve-tracing-lane-detection) and showed real promise on clean gels but didn't fix the worst real over-segmentation case; not merged. See AGENTS.md's Implementation Status and Known Limitations for the full history, findings, and confirmed dead ends (don't re-attempt those without reading why they failed first).
  • 7 real images have a confirmed ground-truth purity % and MW (data/pptx_tet3_gels/ + HpyCH4IV) — every other successful calibration only confirms the calibration machinery works, not that the reported purity % is correct. More confirmed MWs are tracked in QUESTIONS_FOR_USERS.md.
  • Purity calculation is a direct single-lane densitometric ratio (target band area / total lane area, calibrated against one ladder), not a comparison/bracketing against reference lanes — a deliberate choice, see AGENTS.md.
  • No git actions (commit/push) happen without explicit user consent — see AGENTS.md's "Working Agreements".
  • Open questions that need a domain expert's input (not just an engineering call) are tracked in QUESTIONS_FOR_USERS.md, to be asked in a batch rather than piecemeal.

About

A package for extracting data from gel images