5 changes: 5 additions & 0 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -174,10 +174,15 @@ That's the loop: **talk → plan → inspect.** With hardware connected (drop `-

| Guide | Audience | What you'll learn |
|-------|----------|-------------------|
| [Documentation Home](docs/index.md) | Everyone | Browse the generated-docs structure for Gently |
| [Full Stack Microscopy](docs/full-stack-microscopy.md) | Everyone | How intent, samples, hardware, perception, data, and operators fit together |
| [Try Without Hardware](docs/guides/try-offline.md) | Everyone | Run the agent in 10 minutes — conversation, plan mode, perception |
| [What Gently Can Do](docs/guides/capabilities.md) | Everyone | Perception, detection, plan mode, memory, mesh, safety |
| [Build a Plugin](docs/guides/build-a-plugin.md) | Developers | Create organism and hardware plugins for other modalities |
| [Hardware Setup](docs/guides/hardware-setup.md) | Labs | Connect a diSPIM, start the device layer, first acquisition |
| [Sample & Hardware Model](docs/architecture/sample-hardware-domains.md) | Developers | Generalize samples, hardware operations, and device-profile boundaries |
| [Sample Tracking Metrics](docs/architecture/sample-tracking-metrics.md) | Developers | Define reusable sample state, exposure, focus, and perception metrics |
| [Hardware Profile Template](docs/architecture/hardware-profile-template.md) | Developers | Checklist for adding or documenting a new microscope profile |

## Architecture

Expand Down
97 changes: 97 additions & 0 deletions docs/architecture/hardware-profile-template.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,97 @@
# Hardware Profile Template

Use this template when adding or documenting a new hardware profile.

## Profile Identity

- Profile name:
- Primary sample type:
- Primary acquisition modality:
- Device-layer entry point:
- Configuration file(s):

## Standard Operations

| Operation | Supported | Implementation | Notes |
| --- | --- | --- | --- |
| `sample_overview` | yes/no | | |
| `detect_samples` | yes/no | | |
| `move_to_sample` | yes/no | | |
| `focus_scan` | yes/no | | |
| `position_calibration` | yes/no | | |
| `acquire_snapshot` | yes/no | | |
| `acquire_volume` | yes/no | | |
| `set_illumination` | yes/no | | |
| `read_device_state` | yes/no | | |

## Coordinate Frames

List every coordinate frame exposed to the agent or UI.

| Frame | Units | Origin | Axes | Conversion owner |
| --- | --- | --- | --- | --- |
| overview pixels | px | | | |
| stage | | | | |
| acquisition volume | voxels | | | |

Required notes:

- Which frame is stored in `position_coarse`.
- Which frame is stored in `position_fine`.
- Whether any axis is inverted relative to the overview image.
- Which code owns pixel-to-stage transforms.

## Safety Limits

| Device/axis | Lower | Upper | Enforcement layer | How verified |
| --- | --- | --- | --- | --- |
| | | | device `set()` | |
| | | | firmware | |

Every motion source should have a lowest-layer safety limit. If joystick,
manual controls, or vendor UI can bypass Python checks, document the firmware or
operator procedure that closes that path.

## State Reporting

| State field | Source | Poll/callback | Frequency | Read-only |
| --- | --- | --- | --- | --- |
| stage position | | | | yes |
| focus actuator | | | | yes |
| illumination state | | | | yes |
| temperature | | | | yes |

State reporting endpoints must not mutate hardware.

## Data Products

| Product | Format | Storage owner | Metadata required |
| --- | --- | --- | --- |
| overview image | | | sample id, position, pixel size |
| snapshot | | | sample id, channel, exposure |
| volume | | | sample id, voxel size, channel, exposure |

Large arrays should be written by the device layer or persisted once, then
referenced by uid/path. Avoid repeated JSON/base64 transfer for production data.

## Sample Metrics Populated

Check the metrics this profile updates:

- [ ] `position_coarse`
- [ ] `position_fine`
- [ ] `position_history`
- [ ] `exposure_count`
- [ ] `total_exposure_ms`
- [ ] `focus_history`
- [ ] `signal_intensity_history`
- [ ] `perception_runs`

## Test Plan

- [ ] Offline import smoke test
- [ ] Mock device unit tests
- [ ] Hardware availability diagnostic
- [ ] Safety limit rejection test
- [ ] Acquisition dry-run or simulated run
- [ ] Live acquisition test with explicit operator opt-in
104 changes: 104 additions & 0 deletions docs/architecture/sample-hardware-domains.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,104 @@
# Sample and Hardware Domain Model

Gently's current production profile is a diSPIM imaging C. elegans embryos, but
the control model should be described in terms that also fit other microscopes
and sample types. This document defines that vocabulary.

## Design Rule

Application code should talk about samples, observations, acquisitions, and
calibration. Hardware modules translate those concepts to device-specific
plans, device names, and timing details.

The current `Embryo` state is therefore an implementation of a more general
sample state. It should remain useful for C. elegans while keeping fields and
operations that other sample models can reuse.

## Concept Mapping

| Gently concept | Current diSPIM implementation | Other modality examples |
| --- | --- | --- |
| Sample | C. elegans embryo | well, organoid, cell colony, tissue region |
| Sample overview | Bottom-camera widefield image | low-mag confocal tile, plate overview, brightfield montage |
| Sample detection | Embryo detection/marking | well detection, cell segmentation, ROI picking |
| Position calibration | Pixel-to-stage and SPIM alignment | tile registration, well-to-stage map, objective-specific alignment |
| Focus scan | Piezo/galvo focus sweep | Z-stack focus curve, autofocus objective sweep |
| 3D acquisition | Lightsheet volume | confocal Z-stack, widefield deconvolution stack |
| Timepoint | One scheduled sample observation | one image, stack, or multimodal acquisition at a sample/time |
| Perception | VLM/classifier stage reasoning | phenotype call, quality control, event detection |

## Standard Operation Names

Hardware profiles should expose conceptually named operations even when their
device implementation is modality-specific.

| Operation name | Meaning | diSPIM backing operation |
| --- | --- | --- |
| `sample_overview` | Capture a field that can locate samples | bottom camera capture |
| `detect_samples` | Produce sample candidates/ROIs | embryo detector or manual marking |
| `move_to_sample` | Move the instrument to a sample's resolved position | XY stage move |
| `focus_scan` | Search focus around a sample or plane | piezo/galvo focus sweep |
| `position_calibration` | Refine sample position/calibration state | center/verify and SPIM calibration |
| `acquire_volume` | Acquire a 3D observation | lightsheet volume scan |
| `acquire_snapshot` | Acquire a 2D observation | lightsheet snap or overview image |
| `set_illumination` | Configure light source state/power | laser, LED, room light controls |
| `read_device_state` | Report physical state without mutation | device-layer status endpoints |

Names in tool descriptions, plan metadata, logs, and docs should prefer these
general concepts. The hardware package may still contain files named for the
real devices (`bottom_camera`, `galvo`, `piezo`) because those are implementation
details inside the diSPIM profile.

## Layering

1. `gently.core` defines storage, events, coordinates, and image utilities.
2. `gently.harness` defines reusable agent, session, tool, prompt, and planning
mechanics.
3. `gently.organisms` defines biological semantics, such as C. elegans stages.
4. `gently.hardware` defines device profiles and maps standard operations to
concrete devices/plans.
5. `gently.app` composes one organism and one hardware profile into the
microscopy agent.

Domain state should move upward as structured sample records. Raw device
details should stay in the hardware profile unless the UI is explicitly showing
hardware diagnostics.

## Plan Naming Convention

Use `*_plan` for Bluesky/device-layer plans and include the conceptual operation
in the metadata when possible:

```python
_md = {
"plan_name": "acquire_volume",
"operation": "acquire_volume",
"hardware_profile": "dispim",
}
```

Recommended naming:

| Preferred | Avoid for new public API | Reason |
| --- | --- | --- |
| `sample_overview_plan` | `bottom_camera_plan` | overview generalizes beyond diSPIM |
| `focus_scan_plan` | `piezo_sweep_plan` | focus is the user-facing concept |
| `position_calibration_plan` | `center_embryo_plan` | calibration can apply to many samples |
| `acquire_volume_plan` | `lightsheet_only_plan` | volume acquisition is modality-neutral |

Existing diSPIM-specific names do not need churn. New public tools, docs, and
metadata should use the conceptual names and point to the diSPIM implementation.

## Extension Checklist

A new hardware profile should document:

- Which device or plan provides `sample_overview`.
- How sample coordinates map to stage coordinates.
- Which acquisition operations are supported: snapshot, volume, timelapse,
multichannel, burst.
- Which state readings are available without moving hardware.
- Which safety limits are enforced in hardware/device classes.
- Which sample tracking metrics are populated by the profile.

Use `docs/architecture/hardware-profile-template.md` as the starting point.
122 changes: 122 additions & 0 deletions docs/architecture/sample-tracking-metrics.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,122 @@
# Sample Tracking Metrics

Sample tracking metrics describe what happened to a sample over time. They are
kept separate from organism-specific interpretation so they can support embryos,
wells, cells, organoids, or tissue regions.

## Metric Categories

| Category | Purpose | Examples |
| --- | --- | --- |
| Position | Where the sample was observed | coarse XY, fine XY, position history |
| Exposure | How much light/acquisition burden it received | exposure count, total exposure ms |
| Focus | Whether optical focus is stable | focus history, drift rate |
| Signal | Quantitative image measurements | channel intensity, photobleaching curve |
| Perception | Semantic interpretations | developmental stage, health state, event flags |
| Provenance | How the record was produced | detector id, model version, confidence |

## Universal Fields

These fields are broadly useful across sample types and should remain stable
where possible.

| Field | Type | Description |
| --- | --- | --- |
| `sample_id` | string | Stable id within a session. Current C. elegans code uses `embryo_id`. |
| `sample_uid` | string/null | Optional globally meaningful id. Current code uses `uid`/`embryo_uid`. |
| `role` | string | Experimental role such as test, calibration, control, unassigned. |
| `position_coarse` | object/null | Overview/manual position, usually XY stage coordinates. |
| `position_fine` | object/null | Refined acquisition position for the primary objective/modality. |
| `has_fine_position` | bool | True when fine position should override coarse for acquisition. |
| `position_history` | list | Optional time series of positions and sources. |
| `exposure_count` | integer | Number of acquisitions or exposure events. |
| `total_exposure_ms` | number | Integrated illumination/exposure time. |
| `last_imaged` | ISO datetime/null | Last successful observation time. |
| `focus_history` | list | Focus measurements keyed by position, modality, and score. |
| `signal_intensity_history` | object/list | Per-channel measurements over time. |
| `perception_runs` | list | Links to semantic classifications and reasoning traces. |

## Domain-Specific Fields

Domain fields are valuable, but should be clearly scoped to an organism/sample
plugin.

| Field | Current meaning | Scope |
| --- | --- | --- |
| `developmental_stage` | C. elegans morphology stage | C. elegans organism profile |
| `hatching_status` | C. elegans hatch state | C. elegans organism profile |
| `morphology_history` | Stage/shape observations | organism-specific |
| `custom_classifications` | User-defined labels | experiment-specific |

## Position Semantics

Gently distinguishes coarse and fine positions:

- `position_coarse` comes from an overview image, manual marking, or low-mag
sample map.
- `position_fine` comes from a refined alignment step for the acquisition
modality.
- `stage_position` is a compatibility/read convenience: fine if present,
otherwise coarse.

Persistence and import/export code should preserve both positions. Updating the
coarse position should clear or invalidate fine position unless the update is
known not to affect fine alignment.

## Exposure Semantics

Exposure tracking should describe burden on the sample, not simply image count.

Minimum record:

```yaml
sample_id: embryo_1
timepoint: 12
modality: lightsheet_volume
frames: 50
exposure_ms: 10.0
channels:
488nm:
laser_power_pct: 5.0
total_ms: 500.0
created_at: 2026-05-30T12:00:00
```

For multimodal acquisitions, store one record per channel/modality or include a
structured `channels` map. Do not collapse illumination wavelength and camera
exposure into a single ambiguous number.

## Focus Semantics

Focus measurements should include:

- acquisition modality or objective,
- stage position/context,
- focus actuator position,
- score algorithm,
- score value,
- timestamp,
- source: hardware autofocus, FFT, VLM, manual.

This allows drift estimates such as micrometers/hour without tying the schema to
one microscope.

## Perception Provenance

Every semantic decision should be traceable:

- model or detector id,
- input image/volume uid,
- prompt or detector config hash when applicable,
- confidence or score,
- reasoning trace path when available,
- timestamp and triggering event.

This is the bridge between sample tracking and the evaluation/trajectory
debugging systems.

## Compatibility Notes

Current `EmbryoState` fields map directly onto this schema. Future sample types
can either implement their own typed state object or reuse a generic
`SampleState` shape, provided API responses keep the universal fields above.
55 changes: 55 additions & 0 deletions docs/full-stack-microscopy.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,55 @@
# Full Stack Microscopy

Gently should be documented as a microscopy system, not only as an agent or a
device controller. The useful view for a biologist or instrument developer is
the full path from experimental intent to stored evidence.

## Stack Map

| Stack | What it owns | Gently surface |
| --- | --- | --- |
| Experimental intent | Scientific question, hypothesis, controls, success criteria | plan mode, campaigns, plan items |
| Sample preparation | Organism, strain, treatment, mounting, perturbation | sample records, sample-tracking metrics |
| Hardware integration | Microscope devices, safety limits, device state, calibration | hardware profiles, device layer, profile templates |
| Acquisition | Snapshots, volumes, timepoints, illumination, temperature | acquisition tools, Bluesky plans, session metadata |
| Perception | Detection, classification, quality control, event recognition | perception traces, predictions, reasoning records |
| Closed-loop decisions | When to continue, stop, adapt, or ask the operator | agent tools, event logs, decision logs |
| Data and provenance | Raw data, derived data, logs, plans, exports | FileStore/GentlyStore, session directories, debug bundles |
| Operator experience | Setup, monitoring, intervention, recovery | web UI, chat, settings, docs/tutorials |

## Documentation Shape

Generated docs should include three kinds of material:

- Tutorials: task-focused paths such as "run without hardware", "add a hardware
profile", and "start a safe timelapse".
- Concepts: the full-stack map, sample/hardware domain boundaries, and data
provenance expectations.
- References: API surfaces, command-line flags, storage layouts, hardware
profile checklists, and test markers.

## Hardware as One Stack

Hardware is a core stack, but it should not dominate the documentation model.
The device layer matters because it connects intent to physical state safely:
limits, calibration, timing, illumination, and temperature all shape what
scientific claims can be made from the data.

Hardware docs should therefore connect each device profile to:

- the sample state it can observe or change
- the safety boundaries it enforces
- the metadata it records
- the simulator or live-hardware tests that cover it
- the operator workflow for setup and recovery

## Tutorial Roadmap

Priority tutorials:

- run Gently offline and create a plan
- connect a local diSPIM device layer
- add a new hardware profile
- add a new organism/sample type
- inspect a stored session and export a debug bundle
- write a hardware contract test and an opt-in live hardware test
Loading