⚠️ This is a fork of the original Jackery-Official/jackery integration.This fork adds fixes and additional sensors specifically tested with the Jackery SolarVault 3 Pro Max and the Jackery SmartMeter 3P (HTO907A). All credits for the original implementation go to the original authors.
Changes in this fork are tracked in the commit history. Bug reports and improvements relating to this fork can be filed here; for general Jackery integration issues please use the original repository.
With 100+ entities, finding the right sensor can be tricky. → docs/entity-reference.md lists all sensors by category, explains which ones to use for energy dashboards, and explains why SmartMeter sensors are preferred over SolarVault-internal sensors for grid import/export.
Entity IDs follow the pattern:
{domain}.jackery_{sn_lowercase}_{entity_display_name_slug}
Example: SN HS2C12600262HH4 → sensor.jackery_hs2c12600262hh4_solar_power
| Sensor | MQTT field | Description |
|---|---|---|
| Inverter Stack Input Power | stackInPw |
AC power flowing into the inverter stack |
| Inverter Stack Output Power | stackOutPw |
AC power flowing out of the inverter stack |
| BMS SOC | soc |
Combined BMS state of charge across all battery units |
| Battery State | batState |
Current battery operation state (0=transitioning, 1=normal, 2=active) |
| Ethernet Connected | ethPort |
Whether the Ethernet port is connected |
| WiFi Signal | wsig |
WiFi signal strength in dBm |
| Max Inverter Standby Power | maxInvStdPw |
Configured inverter standby power limit |
| Max Grid Standby Power | maxGridStdPw |
Configured grid standby power limit |
| AC to Grid Energy | acOtOngridEgy |
Cumulative AC-to-grid energy |
| CT Import Energy | inCtEgy |
Cumulative system-level CT import energy (added in firmware post-2026-07) |
| CT Export Energy | outCtEgy |
Cumulative system-level CT export energy (added in firmware post-2026-07) |
| SOC Force Charge Target | socForceChg |
See control entities below |
| WiFi SSID | wname |
SSID of the connected WiFi network (empty when Ethernet is active) |
| WLAN IP | wip |
IP address of the SolarVault on the WiFi network |
| Ethernet IP | eip |
Ethernet IP address of the SolarVault |
| Device Capability | ability |
Capability bitmask – changes value after firmware updates |
| Device Status | stat |
Device operation status: normal / waiting / alarm / fault / standby / low_power |
| OnGrid Status | ongridStat |
Grid-tie status: disconnected / connected |
| CT Status | ctStat |
CT meter connection status: disconnected / connected |
| Grid Meter Link | gridSate |
Grid meter link health: not_linked / linked |
| Max Feed Grid Power | maxFeedGrid |
Maximum grid feed-in power reported by the device (from type-106 status) — also writable, see control entities |
| Entity type | Entity | MQTT field | Range / Options | Description |
|---|---|---|---|---|
| Number | SOC Charge Limit | socChgLimit |
0–100 % | Maximum SOC the battery charges to |
| Number | SOC Discharge Limit | socDischgLimit |
0–100 % | Minimum SOC the battery discharges to |
| Select | Max Feed-in Power (OnGrid) | maxOutPw |
800 W / 1200 W / 2500 W | Maximum OnGrid feed-in power (Einspeiseleistung). SV3 Pro: 800/1200 W. SV3 Pro Max: 800/2500 W. Only app-supported values are offered to prevent invalid configurations. |
| Number | Default Output Power | defaultPw |
0–200 W (10 W steps) | Fallback output power for Benutzerdefiniert mode (workModel=4) when no schedule entry is active. App limit: 200 W. Schedule slots (configured in app, cloud-only) can be up to 800 W. |
| Number | Max Grid Feed-In Limit | maxFeedGrid |
0–800 W (10 W steps) | System-level enforced grid feed-in cap. Distinct from "Max Feed-In Power" (which controls maxOutPw, the app-selectable limit of 800/1200/2500 W). Confirmed writable via cmd=5 (Issue #11). |
| Number | SOC Force Charge Target | socForceChg |
0–100 % | |
| Select | Auto Standby Mode | autoStandby |
invalid / standby / on | Controls auto-standby behaviour |
| Select | Work Mode | workModel |
Eigenverbrauch / Benutzerdefiniert / Tarifmodus / KI-Modus | Operating mode selector. Note: tariff/schedule configuration and KI strategy selection are cloud-only and not accessible via local MQTT. |
| Switch | Auto Standby Allowed | isAutoStandby |
on / off | Whether auto-standby is permitted |
| Switch | EPS Switch | swEps |
on / off | Enable/disable EPS (off-grid) output |
| Switch | Off-Grid Fallback | offGridDown |
on / off | Enable off-grid fallback mode |
| Switch | Follow Meter Power (Zähler folgen) | isFollowMeterPw |
on / off | Sub-mode within Benutzerdefiniert (workModel=4): device tracks the SmartMeter to achieve net-zero grid exchange. Only available when Work Mode = Benutzerdefiniert. |
| Button | Reboot | – | – | Sends a restart command to the SolarVault (type=1, cmd=5, reboot=1). Useful to restore SmartMeter LAN mode without touching the device or app. |
The original integration incorrectly classified the Jackery SmartMeter 3P as a smart plug instead of a CT meter (see issue #18). This caused the energy flow calculation to receive no CT data at all.
This fork fixes the classification and exposes 19 dedicated sensors per SmartMeter:
| Sensor | MQTT field | Description |
|---|---|---|
| Grid Import Power | tPhasePw |
Total net grid import power |
| Grid Export Power | tnPhasePw |
Total net grid export power |
| L1/L2/L3 Import Power | a/b/cPhasePw |
Per-phase grid import power |
| L1/L2/L3 Export Power | an/bn/cnPhasePw |
Per-phase grid export power |
| Grid Import Energy | tPhaseEgy |
Cumulative total grid import energy |
| Grid Export Energy | tnPhaseEgy |
Cumulative total grid export energy |
| L1/L2/L3 Import Energy | a/b/cPhaseEgy |
Cumulative per-phase import energy |
| L1/L2/L3 Export Energy | an/bn/cnPhaseEgy |
Cumulative per-phase export energy |
| Communication Mode | commMode |
1 = LAN (local MQTT), 2 = Cloud relay – useful for diagnosing data loss |
| Communication State | commState |
1 = online, 0 = offline |
| IP Address | wip |
IP address of the SmartMeter on the local network |
- Custom Home Assistant integration (no YAML entities required)
- MQTT-based data flow with a shared
JackeryDataCoordinator - Periodic data requests every 10 seconds
- Real-time power sensors (W) and cumulative energy sensors (kWh)
- Battery SoC in percent with proper scaling
- Ready-to-use example configuration for Energy Flow Card Plus
Before the integration can receive data, two things must be in place:
-
MQTT broker configured and reachable
-
Device configured via Jackery app
- Open HACS → Integrations → three dots → Custom repositories
- Add URL:
https://github.com/csoscd/ha-solarvault, Category:Integration - Search for "Jackery SolarVault" and install
- Restart Home Assistant
- Go to Settings → Devices & Services → Add Integration → search "Jackery"
- Enter:
- Device SN: your device serial number (visible in the Jackery app)
- Token: your device token (visible in the Jackery app MQTT settings)
- Topic Prefix:
hb(default)
type: custom:energy-flow-card-plus
entities:
solar:
entity: sensor.jackery_solar_power
name: Solar
icon: mdi:solar-power
grid:
entity:
consumption: sensor.jackery_grid_import_power
production: sensor.jackery_grid_export_power
name: Grid
icon: mdi:transmission-tower
battery:
entity:
consumption: sensor.jackery_battery_charge_power_calc
production: sensor.jackery_battery_discharge_power_calc
state_of_charge: sensor.jackery_bms_soc
name: Battery
icon: mdi:battery
home:
entity: sensor.jackery_home_power
name: Home
icon: mdi:home-lightning-bolt
display_zero_lines:
mode: show
transparency: 50
grey_color: [189, 189, 189]
w_decimals: 0
kw_decimals: 2
color_icons: true
animation_speed: 10
energy_date_selection: falseNote on battery sensors:
sensor.jackery_battery_charge_powerreports the charge power of the main SolarVault unit only.sensor.jackery_battery_charge_power_calcsums the charge power across all connected battery units (e.g. SolarVault 3 Pro Max + BP2500) and is the correct sensor for multi-unit setups.sensor.jackery_bms_socreports the combined BMS state of charge across the entire battery stack and should be preferred oversensor.jackery_battery_socfor multi-unit setups.
If energy-flow-card-plus shows Wh instead of W in your setup, use power-flow-card-plus instead.
It requires a single signed battery power sensor (positive = discharging, negative = charging).
Create a Template sensor helper in Home Assistant with this formula:
{{ states('sensor.jackery_battery_discharge_power_calc') | float(0) - states('sensor.jackery_battery_charge_power_calc') | float(0) }}
Then use it in your card config:
type: custom:power-flow-card-plus
entities:
solar:
entity: sensor.jackery_solar_power
name: Solar
icon: mdi:solar-power
grid:
entity: sensor.jackery_grid_import_power
entity_production: sensor.jackery_grid_export_power
name: Grid
icon: mdi:transmission-tower
battery:
entity: sensor.jackery_battery_net_power_signed # your template sensor
state_of_charge: sensor.jackery_bms_soc
name: Battery
icon: mdi:battery
home:
entity: sensor.jackery_home_power
name: Home
icon: mdi:home-lightning-boltSymptom: SmartMeter power sensors (L1–L3 Import/Export, Grid Import/Export Power) suddenly stop delivering values or show 0 W permanently, even though the SmartMeter appears as available in Home Assistant.
Root cause: commMode switch from LAN → Cloud
The SmartMeter HTO907A can switch on its own from local MQTT mode ("LAN") to Jackery Cloud relay mode ("Cloud") — for example after repeated internet outages. In Cloud mode it still reports its device info to the SolarVault, but no measurement data.
How to identify it:
-
HA sensor
sensor.jackery_<name>_communication_modeshows2instead of11= LAN (local MQTT path, measurement data flows normally)2= Cloud (measurements are relayed via Jackery cloud, not available in HA)
-
Jackery app: The SmartMeter displays "Cloud" instead of "LAN" at the top.
-
MQTT diagnosis: The type-101 event contains
"commMode":2and the measurement fields (tPhasePw,aPhasePw, etc.) are absent from the body entirely.
Fix: restart the SolarVault
Restarting the SolarVault (via the Jackery app or directly on the device) causes the SmartMeter to re-register with the SolarVault and automatically choose the LAN path. After the restart, communication_mode should return to 1 and measurement data should resume.
Note: There is no MQTT command to set commMode directly — the mode is decided by the SmartMeter itself and cannot be overridden via MQTT.
- Original integration: https://github.com/Jackery-Official/jackery
- Energy Flow Card Plus: https://github.com/flixlix/energy-flow-card-plus
- Home Assistant MQTT integration: https://www.home-assistant.io/integrations/mqtt/
uv sync --group test
uv run pytest tests/ -vTests cover energy-flow calculation logic, MQTT message routing (regression tests for the CT-cache bug), sensor value transforms, and config flow integration tests (using the real HA test framework). Coverage is reported after every run; the minimum threshold is 30 %.
uv sync --group lint
uv run ruff check custom_components/jackery/ # linter + import order
uv run mypy custom_components/jackery/ # type checker
python tools/check_translations.py # translation completenessEvery push and pull request runs three GitHub Actions jobs automatically:
| Job | Checks |
|---|---|
| Lint | Ruff, mypy, translation completeness (tools/check_translations.py) |
| Tests | pytest with coverage (--cov-fail-under=30) |
| Validate | HACS validation, Hassfest validation |
Dependabot is configured to keep GitHub Actions versions up to date (weekly, Mondays).
The Jackery Smart Meter D0 Reader (model HTO910A, devType=4, subType=7) reads the optical D0 infrared interface of German electricity meters (IEC 62056-21 / SML protocol). It sits magnetically on the IR port of the meter and reports the total grid import/export power that the meter measures — no per-phase breakdown (the underlying household connection can still be 3-phase).
The device appears in a collectors array within type-101 messages — a field our integration previously
silently ignored. Version 2.2.0 adds full support:
| Sensor | MQTT field | Description |
|---|---|---|
| Grid Import Power | inPw |
Grid import power measured by the HTO910A |
| Grid Export Power | outPw |
Grid export power measured by the HTO910A |
| Communication State | commState |
Online / Offline |
| Communication Mode | commMode |
LAN / Cloud (Relay) |
| IP Address | wip |
HTO910A IP address on the local network |
The HTO910A data also feeds into the jackery_home_power calculation as a CT source (fallback
when the SmartMeter 3P / HTO907A is not present).
maxFeedGrid is now a writable Number entity (0–800 W, step 10 W). Previously it was read-only.
The device-reported value from type-106 is still visible as a separate read-back sensor.
Note:
maxFeedGridis distinct frommaxOutPw(the "Max Feed-In Power" select entity with 800/1200/2500 W options). The exact relationship between the two fields is not fully documented by Jackery, but live captures confirm they can hold different values simultaneously.
New sensor WLAN IP (wip) shows the SolarVault's IP address on the WiFi network.
Useful for network diagnostics alongside the existing Ethernet IP sensor.
New file docs/entity-reference.md explains which sensors
to use for energy dashboards, why SmartMeter sensors are preferred for grid import/export,
and lists all 100+ entities by category with their entity_id patterns.
The German label for the low_power device status state was changed from "Schwachstrom"
to "Energiesparmodus" (more natural phrasing).
A regression in v2.0.0 caused SmartMeter 3P, BP2500, and smart plug entities to never be created (or recreated) after a Home Assistant restart or integration reload. All values were absent; reverting to v2.0.0 was the only workaround (see Issue #7).
Root cause: The coordinator attribute config_entry_id was accidentally renamed to
_config_entry_id (private) in v2.0.0, while the hasattr(self, "config_entry_id")
guards in the sub-device discovery code still checked the old public name.
The guards always evaluated to False, so sub-device entities were never instantiated.
This is fixed in v2.0.2 by restoring the public attribute name.
The v2.0.0 entity migration contained two bugs that left orphaned entities in the HA UI (showing "unavailable" or "unknown" alongside working duplicates):
- Main-device sensors with
battery_*orct_*in their name (e.g.Battery SoC,CT Status) were skipped by the migration and kept their old unique ID — causing them to be re-created as orphaned entities. - Switch and number entities were migrated to the wrong unique-ID format
(
…_main_swEpsinstead of…_switch_swEps), leaving both the wrongly-renamed entity and a fresh duplicate.
v2.0.2 detects and removes these orphaned/wrongly-migrated entities on startup. No manual cleanup needed.
Note for users upgrading from v1.x: After updating and restarting Home Assistant, duplicate "unavailable" entities are removed automatically. A browser hard-refresh (Ctrl+Shift+R) may be needed if the UI still shows stale entries.
The Max Feed-in Power select entity now includes 1200 W (SV3 Pro) as an option,
alongside 800 W and 2500 W (SV3 Pro Max). Previously, SV3 Pro users with 1200 W set
in the app saw "unknown" in the select entity (Issue #5).
The home power formula can temporarily yield a negative result due to asynchronous sensor updates between the SmartMeter and the SolarVault. Since house loads cannot be negative, any negative result is now clamped to 0.
Multiple Jackery devices can now be integrated simultaneously. Each integration entry is identified by its device serial number, so two SolarVaults or other Jackery MQTT devices can coexist in one Home Assistant instance without conflict.
Existing single-device installations are migrated automatically on first startup — entity IDs and HA history are preserved.
If the device reports a token mismatch (MQTT type-123 / error 401), Home Assistant will now show a persistent notification prompting you to re-enter the token. This avoids having to remove and re-add the integration when the token changes.
The HA device card now shows the device model (DIY3 for SolarVault 3 Pro Max) and the firmware version, extracted from incoming MQTT messages. Previously, the device card always showed the generic label "Energy Monitor".
The status sensors Device Status, OnGrid Status, CT Status, and Grid Meter Link now use SensorDeviceClass.ENUM and display human-readable labels (e.g. "Normal", "Connected") instead of raw integers. All labels are translated into English, German, and French.
max_feed_grid_power reads maxFeedGrid from type-106 messages. On some hardware configurations this differs from maxOutPw (the writable max feed-in setting). The new sensor exposes the raw device-side limit for diagnostics.
If a smart plug switches to cloud-relay mode (commMode=2) — which can happen autonomously after internet outages — MQTT switch commands are now blocked. Home Assistant shows a persistent notification explaining that the plug must be controlled via the Jackery App until it returns to LAN mode. The plug's extra_state_attributes expose commMode, commMode_label, and mqtt_controllable for diagnostics and automations.
MIT License – see LICENSE