Notifications
You must be signed in to change notification settings - Fork 1
Expand file tree
/
Copy pathpds.modes
More file actions
149 lines (137 loc) · 8.91 KB
/
Copy pathpds.modes
File metadata and controls
149 lines (137 loc) · 8.91 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
# INSTRUMENT_MODE_ID INSTRUMENT_MODE_DESC
#
# NOTE: There is an unknown upper limit to the length of strings. /Erik P G Johansson 2015-12-17
# The limit has been raised and pds should be able to handle string lengths (incl. CR,LF) up to 1023 bytes. /Erik P G Johansson 2016-01-07
# Not sure, but my memory tells me that the string lengths referred to is the entire length of each row in this file. /Erik P G Johansson 2016-03-08
# NOTE: Older version of pds (before commit 017971e, 2015-12-17) can not handle ":" in descriptions.
# Colon in descriptions yields absent quote in pds. /Erik P G Johansson 2015-12-16
# Updated pds should be able to handle ":" in descriptions. /Erik P G Johansson 2016-01-07
# NOTE: The quotes are the quotes that end up in the LBL files.
# If they are wrong, then the LBL files will be wrong. /Erik P G Johansson 2015-12-17
#
# NOTE: Macros are mostly in sorted numeric order, but not entirely. Third digit (of four) = macro version, so it can also make sense to use that
# as the last character to be used in sorting, i.e. not exactly numeric sorting order. Sorting is inconsistent.
#
0x0000:"Instrument not running any mode"
0x0100:"Transmitting Probe 1 5 KHz"
0x0101:"Transmitting Probe 2 5 KHz"
0x0102:"Transmitting Probe 1 6.7 KHz"
0x0103:"Transmitting Probe 2 6.7 KHz"
0x0104:"Open Sweep Test Calibration"
0x0105:"Internal Resistor Sweep calibration"
0x0106:"Transmitting Probe 1"
0x0107:"Transmitting Probe 2"
0x0200:"Generic macro not for LDL"
0x0201:"Density mode, 20 Bit ADCs truncated, downsampled to 0.83Hz"
0x0202:"Density, normal mode alternating sweeps and time series, version 0."
0x0212:"Density, normal mode alternating sweeps and time series, version 1."
0x0203:"NE mode Sweeping on sensor 1. E-field using 20 bit ADCs on sensor 2 truncated to 16 bits"
0x0204:"Density, Burst mode alternating sweeps and time series."
0x0205:"Density, Full 20 bit data time series"
0x0206:"Generic macro for LDL"
0x0207:"E-field mode, 16 Bit ADCs downsampled 4 times"
0x0300:"EE Mode, 20 Bit ADCs FULL AQP E-Field"
0x0301:"EN Mode, E-Field P1, Density Sweep P2"
0x0302:"Density P1,E-field P2, Fix Dbias 10 V 8KHz Filt. (Sensitive passive mode)"
0x0303:"EE Mode, 16 Bit ADCs 8KHz Filt"
0x0304:"Alternating fine sweeps P1 & P2, Offset 5, Otherwise as Prom Macro 2"
0x0305:"Alternating fine sweeps P1 & P2, Offset 7, Otherwise as Prom Macro 2"
0x0306:"Alternating fine sweeps P1 & P2, Offset 9, Otherwise as Prom Macro 2"
0x0307:"Alternating fine sweeps P1 & P2, Offset 11, Otherwise as Prom Macro 2"
0x0400:"16 Bit ADCs P1 & P1 Down sampling 2 times"
0x0401:"16 Bit ADCs P1 & P1 Down sampling 4 times"
0x0402:"16 Bit ADCs P1 & P1 Down sampling 8 times"
0x0403:"16 Bit ADCs P1 & P1 Down sampling 16 times"
0x0404:"20 Bit ADCs P1 & P2 Down sampling 30 times"
0x0405:"16 Bit ADCs Density Mode P1 & P2 long records 4096*2 samples for Interferometry"
0x0406:"Empty"
0x0416:"EN NM, float/-30V, cont trunc A20 down 128, sweeps P2, HF on P1 down 8"
0x0407:"Empty"
0x0417:"NE NM, -30V/float, cont trunc A20 down 128, sweeps P1, HF on P2 down 8"
0x0410:"EN P1P2 Burst Mode, P1 float, Fix Bias P2 -30V, Cont. 20 bit no down, Sweeps P2 +-30V"
0x0411:"EN BM, float/-30V, cont full A20, /\ sweeps P2, HF on both down 8"
0x0412:"EN BM, float/-30V, cont trunc A20, sweeps P2, HF on both down 8"
0x0413:"EN BM, float/-30V, cont trunc A20, sweeps P2, HF on both down 8"
0x0415:"NE NM, -30V/float, cont trunc A20 down 128, /\ sweeps P1, HF on P2 down 8"
0x0500:"Alternating Log Compressed sweeps P1 & P2, Fix density bias on non sweeping probes"
0x0501:"Alternating Log Compressed sweeps P1 & P2"
0x0502:"Density Difference P1-P2"
0x0503:"EE Cont. 20 bit down 64, Every 160s 16 Bit P1"
0x0504:"EE Cont. 20 bit, Every AQP 16 bit P1 & P2"
0x0505:"Density P1 & P2 Normal Mode, Fix Bias 10V, Cont. 20 Bit down 128,Sweeps P1 & P2 +-18V version 0"
0x0510:"Density P1P2 BM, Vb -30/-30V, Cont. 20 Bit trunc, Sweeps P1 & P2 [-30,+30]V, short HF"
0x0512:"Open sweep calibration 8 kHz"
0x0515:"Density P1 & P2 Normal Mode, Fix Bias 20V, Cont. 20 Bit down 128,Sweeps P1 & P2 -5V to 31V"
0x0516:"Density P1P2 NM, Vb +30/-30V, Cont. 20 Bit trunc down 64, Sweeps P1 & P2 [-26,+31]V, short HF"
0x0414:"Test: 0x516 with bootstrap relay flipped to off"
0x0517:"Density P1P2 NM, Vb -30/-30V, Cont. 20 Bit trunc down 64, Sweeps P1 & P2 [-26,+31]V, short HF"
0x0525:"Density P1P2 NM, Fix Bias +30/-17V, Cont. 20 Bit trunc down 128, Sweeps P1 & P2 [-17,+31]V"
0x0506:"Density 20 bit down 128, 16 bit P1 & P2 and Sweep every 5th AQP"
0x0507:"Empty"
0x0600:"As MCID0x212 but with 20 V bias and 8KHz filters"
0x0601:"Interferometry burst mode, then sweeps as MCID0x212"
0x0611:"NN NM, fix bias -30/-30V, cont trunc A20 down 128, sweeps P1P2, HF on P1 down 8"
0x0610:"NN NM, fix bias +30/-30V, cont trunc A20 down 128, sweeps P1P2, HF on P1 down 8"
0x0602:"Interferometry normal mode, then sweeps as MCID0x212"
0x0612:"NN NM, fix bias -30/-30V, cont trunc A20 down 128, sweeps P1P2, HF on P2 down 8"
0x0603:"As MCID0x212 but with difference measurements"
0x0613:"NN NM, fix bias +30/+30V, cont trunc A20 down 128, sweeps P1P2, HF on P1 down 8"
0x0604:"Sweep P1 and P2, 16 bit interferometry at end, 20 bit cont. throughout, 20V fix bias version 0"
0x0614:"Density P1 & P2 Burst Mode, Fix Bias -30V, Cont. 20 Bit full down 2, Sweeps P1 & P2 +-30V version 1"
0x0615:"NE NM, +30V/float, cont trunc A20 down 128, sweeps P1, HF on P2 down 8"
0x0616:"EN NM, float/+30V, cont trunc A20 down 128, sweeps P2, HF on P1 down 8"
0x0617:"Density,Cont. 20 bit full, LDL BM, 16 bit and Sweep P1, Vb +30V"
0x0624:"Density P1P2 Burst Mode, Fix Bias +30/-30V, Cont. truncated no down, Sweeps P1 & P2 +-30V version 2"
0x0605:"Empty"
0x0606:"Empty"
0x0607:"Empty"
0x0700:"E-Field,Cont. 20 Bit down 64, Every 96s 16 Bit diff"
0x0701:"E-Field,Cont. 20 Bit down 64, Every 96s 16 Bit diff"
0x0702:"E-Field,Cont. 20 Bit down 64, Every 96s 16 Bit diff"
0x0703:"E-Field,Cont. 20 Bit trunc down 32, LDL NM, 16 Bit P1 every 3rd AQP"
0x0704:"E-Field,Cont. 20 Bit trunc,LDL BM,16 Bit P1 every AQP"
0x0705:"E-Field,Cont. 20 Bit down 64, Every 160s 16 bit diff"
0x0706:"E-field,Cont. 20 Bit, Every AQP 16 Bit diff"
0x0707:"NM cal A20/A16: NN, Vb 0/0 V, cont A20 down 64, A16 every 160s, no swp"
0x0710:"NM EE with sweep P2, LF EE down 256 but last AQP down 8, HF EE down 8"
0x0712:"Cal macro with /\ sweeps, alternating open probe and resistor"
0x0715:"NM LDL Efloat, 14Hz snapshots trunc A20, HF down 8"
0x0716:"NM LDL Efloat, cont trunc A20, HF down 8"
0x0800:"EE Cont. 20 bit down 128, Every 160s 16 Bit P1 & P2"
0x0801:"EE float Cont. 20 bit down 128, Every 160s 16 Bit P1 & P2"
0x0802:"EE float Cont. 20 bit, Every AQP 16 bit P1 & P2"
0x0812:"As MCID0X212, Density, normal mode alternating sweeps and time series."
0x0803:"Density Cont. 20 bit trunc down 32,LDL NM,16 bit P1 every 3rd AQP"
0x0804:"Density Cont. 20 bit trunc, LDL BM, 16 bit P1 every AQP"
0x0805:"Density P1 NM, LDL, Fix Bias -22V, Cont. A20 down 64, Sweeps P1 +-30V"
0x0806:"Minimum TM,Normal LDL or mixed LDL"
0x0807:"Density,Cont. 20 bit trun, LDL BM, 16 bit and Sweep P1"
0x0814:"Density P1 NM, LDL, Vb -30V, Cont. 20 Bit trunc down 32, Sweeps +-30V, short HF"
0x0816:"Density P1 NM, LDL, Vb +30V, Cont. 20 Bit trunc down 32, Sweeps +-30V, short HF"
0x0817:"Density,Cont. 20 bit trun, LDL BM, 16 bit and Sweep P1, Vb +30V"
0x0827:"Density,Cont. 20 bit trun, LDL BM, 16 bit and Sweep P1, Vb -30V"
0x0900:"BM NN, Vb +30/-30V, lo/hi, cont A20 trunc, every 160s P1 & P2 swp +-30V & A16"
0x0910:"NM EE with sweep P1, LF EE down 256 but last AQP down 8, HF EE down 8"
0x0901:"BM NN, Vb +30/+30V, hi/hi, cont A20 trunc, every 160s P1 & P2 swp +-30V & A16"
0x0902:"Empty"
0x0903:"BM NN, Vb +30/+30V, lo/lo, cont A20 trunc, every 160s P1 & P2 swp +-30V & A16"
0x0904:"Density P1P2 Burst Mode, Fix Bias +30/-30V, Cont. truncated no down, Sweeps P1 & P2 +-30V as 0x0624"
0x0905:"Density P1P2 NM lo, Vb +30/-17V, Cont. 20 Bit trunc down 128, Sweeps P1 & P2 [-17,+31]V"
0x0906:"Normal TM,Normal LDL or mixed LDL"
0x0916:"Density P1P2 Normal Mode, Fix Bias +30/+30V, Cont. truncated, Sweeps /\ P1 & P2 +-30V, experimental sweeps"
0x0907:"Empty"
0x0917:"Density P1P2 Normal Mode, Fix Bias -30/-30V, Cont. truncated, Sweeps /\ P1 & P2 +-30V, experimental sweeps"
0x0912:"As MCID0X212, Density, normal mode alternating sweeps and time series."
0x0922:"Density P1P2 Burst Mode, Fix Bias -30/-30V, Cont. truncated, Sweeps /\ P1 & P2 +-30V, experimental sweeps"
0x0914:"Density P1P2 Normal Mode, Fix Bias -30/-30V, Cont. truncated no down, Sweeps P1 & P2 +-30V"
0x0926:"Density P1P2 Burst Mode, Fix Bias +30/-30V, Cont. truncated no down, Sweeps P1 & P2 +-30V up-down"
0x0A00:"Empty"
0x0A01:"BM NN, Vb +30/+30V, hi/hi, cont A20 trunc, every 160s P1 & P2 swp +-30V & A16"
0x0A02:"Empty"
0x0A12:"As MCID0X212, Density, normal mode alternating sweeps and time series."
0x0A03:"Empty"
0x0A04:"Empty"
0x0A05:"Empty"
0x0A06:"Burst TM,Normal LDL or mixed LDL"
0x0A07:"NM cal A20/A16: NN, Vb 0/0 V, cont A20 down 64, A16 every 160s, no swp"
0xFFFF:"Instrument mode stopped"