Skip to content

HostTime: barPhase output incorrect for Bars/4 and Bars/8 divisions #919

@caiomarinello

Description

@caiomarinello

Version

26.02

Plugin type

VST3

OS

Windows 11

DAW / Host (if applicable)

Ableton Live 12 Suite – Version 12.3.2

Description

When using the Bar Phase output from the Cardinal Host Time module with Bars/4 or Bars/8 selected, the voltage
does not sweep smoothly from 0 to 10V across the full bar division.

Instead, the phasor resets at different voltages each cycle. For example
with Bars/4 in 4/4 time:

  • Bar 1: 0 to ~2.5V
  • Bar 2: ~0.6 to ~3.1V
  • Bar 3: ~1.2 to ~3.7V
  • Bar 4: ~1.8 to ~4.3V
  • Bar 5: resets back to 0 to ~2.5V

The expected behavior shoul be a smooth 0 to 10V phasor across all 4 bars.

This is caused by the barPhase formula not normalizing beat position
into fractional bars before applying the modulo operation.

Fixed in PR #918